1 Voltage
Charging voltage DC: 8.4V CC/CV
Balance voltage for single cell
2 Current
Balance current for single cell
Current consumption Max: 20µA
Maximal continuous charging current 10A
Maximal continuous Discharging current 10A
3 Over charge Protection
Over charge detection voltage for single cell 4.25V ± 0.025V
Over charge detection delay time 0.5 - 1.8S
Over charge release voltage for single cell 4.05 ± 0.05V
4 Over discharge protection
Over discharge detection voltage for single cell 2.50V ± 0.08V
Over discharge detection delay time 50 - 170ms
Over discharge release voltage for single cell 3.0 ± 0.1V
5 Over current protection
Over current detection voltage 100 ± 30mv
Over current detection current 19 ± 3A
Detection delay time 5 - 15ms
Release condition cut load
6 Short protection
Detection condition Exterior short circuit
Detection delay time 200-500us
Release condition cut load
7 Resistance Protection circuitry(MOSFET) ≤ 60mΩ
8 Temperature
Operating Temperature Range -20 ~ +60°C
Storage Temperature Range -20 ~ +65°C9 Dimension
L48*W9*T2.5mm
top of page
₹150.00Price
May be interested in
bottom of page