1 Voltage
Charging voltage DC: 3.6V CC/CV
Balance voltage for single cell
2 Current
Balance current for single cell
Current consumption ≤ 10µA
Maximal continuous charging current 10A
Maximal continuous Discharging current 10A
3 Over charge Protection
Over charge detection voltage for single cell 3.9V ± 0.025V
Over charge detection delay time 0.5s - 2s
Over charge release voltage for single cell 3.8V ± 0.05V
4 Over discharge protection
Over discharge detection voltage for single cell 2.0V ± 0.05V
Over discharge detection delay time 50ms - 200ms
Over discharge release voltage for single cell 2.5 ± 0.10V
5 Over current protection
Over current detection voltage 0.15 ± 0.03V
Over current detection current 30 ± 3A
Detection delay time 9ms - 11ms
Release condition Cut load
6 Short protection
Detection condition Exterior short circuit
Detection delay time 320 - 500us
Release condition Cut load
7 Resistance Protection circuitry (MOSFET) ≤ 60mΩ
8 Temperature
Operating Temperature Range -20 ~ +70°C
Storage Temperature Range -40 ~ +125°C9 Dimension
L30*W9*T2.3mm